Utility of intra-operative capnogram to detect branch pulmonary artery obstruction following total correction of tetralogy of fallot


Department of cardiac anesthesia and cardiac surgery, Narayana Hrudayalaya Institute of Medical Sciences, Anekal Taluk, Bangalore, India

Correspondence Address:
Rajnish Garg
Narayana Hrudayalaya Institute of Medical Sciences, 258/A, Bommasandra Industrial Area, Anekal Taluk, Bangalore 560 099
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-9784.74399

Rights and Permissions

Year : 2011  |  Volume : 14  |  Issue : 1  |  Page : 45-47

 

SEARCH
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles

  Article in PDF (526 KB)
Email article
Print Article
Add to My List
Branch pulmonary artery obstruction is one of the prime reasons for re-operation in patients who have undergone repair for tetralogy of Fallot. Branch pulmonary artery obstruction may develop over a period of time due to dilation of right ventricular outflow tract or it may be caused by residual stenosis after inadequate repair. This may lead to differential lung perfusion causing morbidity. Intra-operative capnogram monitoring reveals ventilation−perfusion relationship. We report two cases where the capnogram helped the diagnosis and management of branch pulmonary artery obstruction. We found a redundant patch in the first and an extra length of the homograft in second case which led to the obstruction. However, but for the changes in the intraoperative capnogram, this condition may by far remain undiagnosed considering the fact that it does not produce hemodynamic changes but can lead to postoperative morbidity.






[FULL TEXT] [PDF]*
 

 

 

 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 
 
 Reader Comments
 Email Alert *
  *
 * Requires registration (Free)
 
 CASE REPORT
 




Department of cardiac anesthesia and cardiac surgery, Narayana Hrudayalaya Institute of Medical Sciences, Anekal Taluk, Bangalore, India

Correspondence Address:
Rajnish Garg
Narayana Hrudayalaya Institute of Medical Sciences, 258/A, Bommasandra Industrial Area, Anekal Taluk, Bangalore 560 099
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-9784.74399

Rights and Permissions

Branch pulmonary artery obstruction is one of the prime reasons for re-operation in patients who have undergone repair for tetralogy of Fallot. Branch pulmonary artery obstruction may develop over a period of time due to dilation of right ventricular outflow tract or it may be caused by residual stenosis after inadequate repair. This may lead to differential lung perfusion causing morbidity. Intra-operative capnogram monitoring reveals ventilation−perfusion relationship. We report two cases where the capnogram helped the diagnosis and management of branch pulmonary artery obstruction. We found a redundant patch in the first and an extra length of the homograft in second case which led to the obstruction. However, but for the changes in the intraoperative capnogram, this condition may by far remain undiagnosed considering the fact that it does not produce hemodynamic changes but can lead to postoperative morbidity.