ORIGINAL ARTICLE: JANAK MEHTA AWARD WINNER 2015-16  
Year : 2016  |  Volume : 19  |  Issue : 2  |  Page : 231-239
Monitoring diastolic dysfunction using a simplified algorithm in patients undergoing off - pump coronary artery bypass grafting surgery


1 Department of Cardiac Anesthesia, Ozone Anesthesia Group, United CIIGMA Hospital, Aurangabad, Maharashtra, India
2 Department of Cardiac Surgery, United CIIGMA Hospital, Aurangabad, Maharashtra, India
3 Department of Anesthesia, Fortis Hospital, Bengaluru, Karnataka, India
4 Department of Cardiac Anesthesia, Nayati Super-Specialty Hospital, Mathura, Uttar Pradesh, India

Click here for correspondence address and email

Date of Submission31-Dec-2015
Date of Acceptance03-Mar-2016
Date of Web Publication1-Apr-2016
 

   Abstract 

Context: Left ventricle diastolic dysfunction (LVDD) is gaining importance as useful marker of mortality and morbidity in cardiac surgical patients. Different algorithms have been proposed for the intraoperative grading of DD. Knowledge of the particular grade of DD has clinical implications with the potential to modify therapy, but there is a paucity of literature on the role of diastolic function evaluation during off-pump coronary artery bypass grafting (OPCABG) surgery. Aims: The aim of this study was to monitor changes in LVDD using simplified algorithm proposed by Swaminathan et al. in patients undergoing OPCABG. Settings and Design: The study was conducted in a tertiary care level hospital; this was a prospective, observational study. Subjects and Methods: Fifty consecutive patients undergoing OPCABG were enrolled. Hemodynamic and echocardiographic parameters were measured at 6 stages in every patient namely after anesthetic induction (baseline), during left internal mammary artery (LIMA) to left anterior descending (LAD) grafting (LIMA → LAD), saphenous vein graft (SVG) to obtuse marginal (OM) grafting (SVG → OM), SVG to posterior descending artery (PDA) grafting (SVG → PDA), during proximal anastomosis of SVG to aorta, and postprotamine. The patients were classified in grades of LVDD as per simplified algorithm proposed by Swaminathan et al. using only intraoperatively measured E and E'. Results: The success rate of measurement and classification of LVDD was 98.92% (277 out of 280 measurements). The grades of LVDD varied significantly as per surgical steps with maximum downgrading occurring during OM and LAD grafting. During OM grafting, none of the patients had normal diastolic function while 29% of patients exhibited restrictive pattern (Grade 3 LVDD). Patients with normal baseline LV diastolic function also exhibited downgrading during OM and LAD grafting. Postprotamine, 37% of patients with normal baseline diastolic function continued to exhibit some degree of DD. Conclusions: The LVDD changes dynamically during various stages of OPCABG, which can be successfully monitored with simplified algorithm.

Keywords: Diastolic dysfunction; Left ventricle; Off-pump coronary artery bypass grafting

How to cite this article:
Borde DP, Asegaonkar B, Apsingekar P, Khade S, Futane S, Khodve B, Kedar M, Deodhar A, Takalkar U, George A, Joshi S. Monitoring diastolic dysfunction using a simplified algorithm in patients undergoing off - pump coronary artery bypass grafting surgery. Ann Card Anaesth 2016;19:231-9

How to cite this URL:
Borde DP, Asegaonkar B, Apsingekar P, Khade S, Futane S, Khodve B, Kedar M, Deodhar A, Takalkar U, George A, Joshi S. Monitoring diastolic dysfunction using a simplified algorithm in patients undergoing off - pump coronary artery bypass grafting surgery. Ann Card Anaesth [serial online] 2016 [cited 2020 Aug 11];19:231-9. Available from: http://www.annals.in/text.asp?2016/19/2/231/179591



   Introduction Top


Left ventricle diastolic dysfunction (LVDD) refers to an abnormality of ventricular relaxation, compliance, or filling that results in the requirement for an elevated left atrial (LA) pressure to achieve left ventricular filling. [1] Echocardiographically identified DD has been reported to be an independent predictor of morbidity-mortality in variety of surgeries. [2],[3],[4],[5],[6],[7],[8] As per ASE/EAE recommendations, LVDD is assessed by the integrated use of multiple echocardiographic (echo) parameters including spectral Doppler analysis of mitral inflow and pulmonary venous flow, propagation velocity (Vp) of mitral inflow, and tissue Doppler indices of mitral annular motion. [1]

To date, at least five different algorithms have been proposed for the intraoperative grading of LVDD. [1],[9],[10],[11],[12] Swaminathan et al. have proposed highly simplified algorithm using only intraoperatively measured E and E'. It was observed that increasingly severe grades of DD were significantly associated with reduced long-term freedom from a composite endpoint of major adverse cardiac events (MACEs) in 905 patients undergoing isolated CABG surgery. [9]

Hemodynamic management of patients undergoing off-pump coronary artery bypass grafting (OPCABG) is challenging. Transesophageal echocardiography (TEE) is extremely important monitoring tool. [13] Knowledge of the particular stage of DD has clinical implications with the potential to modify therapy. [10] However, the role of diastolic function evaluation during OPCABG surgery has not been well reported.

The aim of this study was to monitor changes in LVDD using simplified algorithm proposed by Swaminathan et al. in patients undergoing OPCABG.


   Subjects and methods Top


Fifty-one consecutive patients undergoing OPCABG were enrolled in this study. One patient was converted to on-pump CABG in view of hemodynamic instability while doing obtuse marginal (OM) grafting. The final analysis included fifty patients. The review board approved this study with waiver off to take separate consent. All patients underwent surgery by midline sternotomy. Standardized anesthesia protocol consisted of general anesthesia with midazolam, fentanyl, and propofol. Vecuronium was used as muscle relaxant. Anesthesia was maintained with boluses of fentanyl, midazolam, and isoflurane as inhalational agent. Monitoring consisted of arterial blood pressure measured by femoral arterial catheter and pulmonary artery catheter inserted by the right internal jugular vein before induction. Surgical steps consisted of midline sternotomy, harvesting of the left internal mammary artery (LIMA) and saphenous vein grafts (SVGs), adequate heparinization (target activated clotting time >300 s), LIMA to left anterior descending (LAD) grafting, and then as per severity of the coronary artery lesion remaining grafts on OM and posterior descending artery (PDA). After the grafting heparin was reversed with protamine, hemostasis was achieved and wound was closed in layers. A single surgical team performed all surgeries.

A TEE probe was gently inserted after induction and TEE images acquired and stored in Acuson X 500 Siemens Echo Machine. Hemodynamic and echo parameters were measured at 6 stages in every patient namely after anesthetic induction (baseline), during LIMA to LAD grafting (LIMA → LAD), SVG to OM grafting (SVG → OM), SVG to PDA grafting (SVG → PDA), during proximal anastomosis of SVG to aorta, and postprotamine. All the measurements were made after hemodynamic stability was achieved, for example, the measurements were made after passing intracoronary shunt when the distal anastomosis was performed. When more than one graft was performed in a territory the values were averaged. All measurements were made in real-time and stored for analysis.

The details of echo measurements are as follows: Transmitral Doppler consisted of measurement of E-wave velocity, A-wave velocity, E/A ratio, and deceleration time performed in the mid-esophageal 4-chamber view. A pulsed wave (PW) Doppler sample volume was placed at the mitral leaflet tips. Spectral recordings were made at end-expiration, when feasible, at a sweep speed of 50-100 mm/s depending on heart rate. Measurements were not averaged over several cycles, but the most representative waves were chosen for measurements. To ensure proper alignment, color flow Doppler was performed before PW Doppler interrogation to visualize the direction of blood flow since the direction of mitral inflow may vary depending on the underlying pathology and varying position of the heart. Mitral annular motion was assessed in the mid-esophageal 4-chamber view with the Doppler beam aligned as parallel as possible to the axis of motion of the cardiac tissue being measured. A sample volume was placed on the lateral annulus within 1 cm of the mitral leaflet insertion sites. The velocity scale was reduced to 20 cm/s from baseline, and the sweep speed is adjusted to approximately 50-100 mm/s; most representative waves were chosen for measurements.

The patients were classified in grades of LVDD as per simplified algorithm proposed by Swaminathan et al. [Figure 1].
Figure 1: Simplified algorithm proposed by Swaminathan et al

Click here to view



   Results Top


Baseline characteristics of fifty patients are as shown in [Table 1].
Table 1: Baseline characteristics of 50 patients


Click here to view


An echo measurement for DD by simplified algorithm at baseline was possible in all fifty patients. In 49 patients undergoing LIMA → LAD, echo measurement was possible in all patients; OM was done in 43 patients and PDA grafting was done in 41 patients and echo measurement was possible in 42 and forty patients, respectively; in one patient, echo measurement was not possible at proximal grafting; echo measurement was successfully carried out in all 50 patients postprotamine. Thus, the success rate of measurement and classification of DD was 98.92% (277 out of 280 measurements). The main reason for unsuccessful measurement was inability to obtain good mitral annular motion.

The hemodynamic parameters at various stages of surgery are as shown in [Table 2].
Table 2: The hemodynamic parameters at various stages of surgery


Click here to view


The echo parameters at various stages of surgery are as shown in [Table 3].
Table 3: The echocardiographic parameters at various stages of surgery


Click here to view


The patients' grades of DD as per various stages of surgery are as shown in [Table 4] and [Figure 2]. To describe the dynamic nature of this change, "motion charts" using Google Spreadsheets were used [Videos 1-4]. A motion chart is a dynamic bubble chart which allows efficient and interactive exploration and visualization of longitudinal multivariate data. The grades of DD varied significantly as per surgical steps with maximum downgrading occurring during OM and LAD grafting. During OM grafting, none of the patients had normal diastolic function while 29% of patients exhibited restrictive pattern (Grade 3 LVDD).
Figure 2: The patients' grades of diastolic dysfunction as per various stages of surgery

Click here to view
Table 4: Patients' grades of diastolic dysfunction as per various stages of surgery


Click here to view














Patients with normal baseline LV diastolic function also exhibited downgrading during OM and LAD grafting. Postprotamine, 37% of patients with normal baseline diastolic function continued to exhibit some degree of DD as shown in [Figure 3] and Video 2.
Figure 3: Changes in grades of diastolic dysfunction in baseline normal function

Click here to view


A representative patient's transmitral PW Doppler and TDI are shown in [Figure 4], [Figure 5], [Figure 6], [Figure 7], [Figure 8], [Figure 9], [Figure 10], [Figure 11], [Figure 12], [Figure 13], [Figure 14] and [Figure 15].
Figure 4: Transmitral pulsed wave Doppler at baseline

Click here to view
Figure 5: Tissue Doppler imaging at baseline

Click here to view
Figure 6: Transmitral pulsed wave Doppler at left internal mammary artery ?#179; left anterior descending

Click here to view
Figure 7: Tissue Doppler imaging at left internal mammary artery → left anterior descending

Click here to view
Figure 8: Transmitral pulsed wave Doppler at saphenous vein graft → obtuse marginal

Click here to view
Figure 9: Tissue Doppler imaging at saphenous vein graft → obtuse marginal

Click here to view
Figure 10: Transmitral pulsed wave Doppler at saphenous vein graft → posterior descending artery

Click here to view
Figure 11: Tissue Doppler imaging at saphenous vein graft → posterior descending artery

Click here to view
Figure 12: Transmitral pulsed wave Doppler at proximal

Click here to view
Figure 13: Tissue Doppler imaging at proximal

Click here to view
Figure 14: Transmitral pulsed wave Doppler at postprotamine

Click here to view
Figure 15: Tissue Doppler imaging at postprotamine

Click here to view



   Discussion Top


The main findings of this observational study are LVDD changes dynamically in patients undergoing OPCABG as per surgical stages with maximum downgrading occurring during OM and LAD grafting. This can be successfully classified with the help of a simplified algorithm proposed by Swaminathan et al. in 98.92% (277 out of 280) measurements. Even in patients with normal baseline diastolic function, there is a downgrading of LVDD, particularly during OM grafting, around one-third of patients with normal baseline diastolic function continued to exhibit some degree of DD postprotamine.

It is now well established that diastolic function, just as systolic function, has clinical, therapeutic, and prognostic implications. An observational study by Afilalo et al. documented that preoperative DD as evidenced by restrictive filling was a strong predictor of mortality with odds ratio of 2.96. [2] Bernard et al. reported that abnormal diastolic filling patterns were frequently observed particularly in patients with altered LV function. DD present before cardiopulmonary bypass (CPB) was associated with an increased risk of difficulty in separation from CPB and vasoactive support in the Intensive Care Unit. [3] Same group of investigators from Montreal, Canada, in another study reported that moderate and 
severe 
LVDDs 
and 
right ventricular DD could be
 identified 
with 
very good reproducibility, and both 
degrees of 
diastolic 
dysfunction 
were associated 
with 
difficulty in separation from CPB. [12] New or worsened DD after CABG surgery is associated with an increased incidence of postoperative atrial fibrillation. [4] There is evidence suggesting that moderate to severe DD in patients with aortic stenosis is an independent predictor of late mortality after valve replacement. [5] The presence of perioperative DD as assessed with Vp is an independent predictor of postoperative congestive heart failure and prolonged length of stay after major vascular surgery. [6] Despite this, a recent multinational survey on TEE suggests that only 46% of academic centers currently perform an assessment of diastolic function routinely during cardiac surgery. [14]

There is evidence supporting that preoperative DD is associated with poor outcome in patients undergoing OPCABG. In a large study of 1048 patients undergoing OPCABG, the authors evaluated the prognostic implications of preoperative estimated LV filling pressure, assessed by E/E' ratio which was an independent predictor of 30-day and 1-year MACE. The recommended measurements of E/E' may assist in preoperative risk stratification of these patients. [7] In another study, E/E' ratio >15 was a significant predictor of composite endpoints of postoperative morbidity. [8] Another study suggested that even in patients with preserved systolic LV function, patients with E/E'>15 were more prone to undergo a significant decrease in cardiac output during OPCAB, which did not return to baseline level after completion of grafting. [15] In contrast to preoperative dysfunction, our study has evaluated intraoperative stage wise changes in DD in patients undergoing OPCABG. About one-third of patients with normal baseline function did not return to normal, but whether these changes in DD is associated with poor outcome remains to be evaluated.

Knowledge of the particular stage of DD has clinical implications with the potential to modify therapy. [10],[16],[17] During the impaired relaxation phase, the mainstay of treatment is increasing preload and reducing heart rate to allow for adequate LV filling. Patients in the decreased compliance stage have an increased LA pressure at baseline, i.e., preload intolerant, thus requiring a careful perioperative fluid management and the judicious use of diuretics. Furthermore, they may require a higher aortic pressure to increase the coronary perfusion pressure owing to an increased LVEDP. The appreciation of these fine differences between the stages of DD can further optimize perioperative management and possibly improve outcome.

To date, at least five different algorithms have been proposed for the intraoperative grading of DD. [1],[9],[10],[11],[12] Some of these algorithms are very complex to be used in the busy environment of operating rooms; some are not validated while using some of these guidelines result in inability to classify a large proportion of patients. A simplified approach is highly desirable intraoperatively owing to the limited time frame for TEE examination. However, any grading system, regardless of simplicity, is irrelevant unless it provides prognostic information by identifying those at risk of adverse outcomes.

The simplified algorithm suggested by Swaminathan et al. [9] fulfills most of these criteria. It is simple, can be rapidly used in intraoperative period, and is validated in cardiac surgical population. Using the highly simplified algorithm using only intraoperatively measured E and E', increasingly severe grades of DD were significantly associated with reduced long-term freedom from a composite endpoint of MACE in 905 patients undergoing isolated CABG surgery. [9] In contrast, strict application of a comprehensive algorithm in keeping with ASE guidelines to grade DD provided no clear association between grade of dysfunction and MACE-free survival. In our study also, we could assign a particular grade of DD to around 98% patients during all stages of OPCABG.

The hemodynamic management during OPCABG is challenging. It is advocated that TEE should be used in all patients undergoing OPCBAG. [13],[18] Gurbuz et al. [19] looked at the effect of intraoperative TEE on OPCAB patients specifically. Seven hundred forty-four OPCAB patients who had intraoperative TEE were retrospectively studied. They found that TEE revealed previously undiagnosed intracardiac pathology in 1.3% of patients, with major modification in a surgical procedure. An intra-aortic balloon pump was placed in 3.2% of patients at the start of the procedure after intraoperative TEE revealed severe left ventricular dysfunction that had previously been underappreciated. Severe aortic atheromatous disease was found in 4.1% of patients, and all of these patients had a change in surgical plan to a no-touch aorta technique with complete arterial revascularization. In another series of 500 patients undergoing OPCABG, Mishra et al. [20] observed that was development of new regional wall motion abnormalities in 59.2% and a decrease in global left ventricular functions in 61.2%. Obstruction of the right ventricular outflow tract was observed on TEE at various stages during vertical displacement of the heart. The authors concluded that the use of intraoperative TEE was valuable in enhancing the safety of the procedure.

However, intraoperative patterns of change in echocardiographic patterns of diastolic function, as well as their clinical significance, remain poorly defined. We could describe a particular pattern of DD using this simplified algorithm. Maximum DD occurred during OM and LAD grafting. None of the patients had normal diastolic function during OM grafting. Two-thirds of the patients with normal baseline function returned to normal values postprotamine. It remains to be ascertained whether applying particular therapy can improve outcomes depending on the grade of DD.

There can be various explanations to these changes. Tachycardia and rhythm disturbances may occur due to hypovolemia, anemia, or electrolyte imbalances and may impair left ventricular filling. [17] Patients may develop mitral regurgitation due to positioning of the heart particularly while performing OM grafting. [21] DD can be an early marker of ischemia. Myocardial ischemia affects the processes underlying systolic inactivation, that is, calcium extrusion from the cytosol and cross-bridge detachment, and will result in delayed relaxation. Adequate relaxation depends on systolic events such as timing, velocity, and synchronicity of contraction, increased left ventricular afterload, and wall stress, and left ventricular dyssynchronous contraction results in delayed and incomplete relaxation. [17]

This study has some notable limitations. The study is limited to only intraoperative period; we do not have similar preoperative data or postoperative follow-up. A study with postoperative follow-up with larger patient population undergoing OPCABG is highly desirable. This study consisted of a limited number of patients operated by a single surgical team; varying results are highly possible with different patients' population and expertise.

Acknowledgment

The authors would like to thank Dr. Madhav Swaminathan (MD, FASE) Duke University, USA, for his expert review of this manuscript. The authors would like to thank Mr. Ninad Lanke for his technical help in preparing videos for this manuscript.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
   References Top

1.
Nagueh SF, Appleton CP, Gillebert TC, Marino PN, Oh JK, Smiseth OA, et al. Recommendations for the evaluation of left ventricular diastolic function by echocardiography. J Am Soc Echocardiogr 2009;22:107-33.  Back to cited text no. 1
    
2.
Afilalo J, Flynn AW, Shimony A, Rudski LG, Agnihotri AK, Morin JF, et al. Incremental value of the preoperative echocardiogram to predict mortality and major morbidity in coronary artery bypass surgery. Circulation 2013;127:356-64.  Back to cited text no. 2
    
3.
Bernard F, Denault A, Babin D, Goyer C, Couture P, Couturier A, et al. Diastolic dysfunction is predictive of difficult weaning from cardiopulmonary bypass. Anesth Analg 2001;92:291-8.  Back to cited text no. 3
    
4.
Ashes CM, Yu M, Meineri M, Katznelson R, Carroll J, Rao V, et al. Diastolic dysfunction, cardiopulmonary bypass, and atrial fibrillation after coronary artery bypass graft surgery. Br J Anaesth 2014;113:815-21.  Back to cited text no. 4
    
5.
Gjertsson P, Caidahl K, Farasati M, Odén A, Bech-Hanssen O. Preoperative moderate to severe diastolic dysfunction: A novel Doppler echocardiographic long-term prognostic factor in patients with severe aortic stenosis. J Thorac Cardiovasc Surg 2005;129:890-6.  Back to cited text no. 5
    
6.
Matyal R, Hess PE, Subramaniam B, Mitchell J, Panzica PJ, Pomposelli F, et al. Perioperative diastolic dysfunction during vascular surgery and its association with postoperative outcome. J Vasc Surg 2009;50:70-6.  Back to cited text no. 6
    
7.
Lee EH, Yun SC, Chin JH, Choi DK, Son HJ, Kim WC, et al. Prognostic implications of preoperative E/e' ratio in patients with off-pump coronary artery surgery. Anesthesiology 2012;116:362-71.  Back to cited text no. 7
    
8.
Jun NH, Shim JK, Kim JC, Kwak YL. Prognostic value of a tissue Doppler-derived index of left ventricular filling pressure on composite morbidity after off-pump coronary artery bypass surgery. Br J Anaesth 2011;107:519-24.  Back to cited text no. 8
    
9.
Swaminathan M, Nicoara A, Phillips-Bute BG, Aeschlimann N, Milano CA, Mackensen GB, et al. Utility of a simple algorithm to grade diastolic dysfunction and predict outcome after coronary artery bypass graft surgery. Ann Thorac Surg 2011;91:1844-50.  Back to cited text no. 9
[PUBMED]    
10.
Mahmood F, Jainandunsing J, Matyal R. A practical approach to echocardiographic assessment of perioperative diastolic dysfunction. J Cardiothorac Vasc Anesth 2012;26:1115-23.  Back to cited text no. 10
    
11.
Matyal R, Skubas NJ, Shernan SK, Mahmood F. Perioperative assessment of diastolic dysfunction. Anesth Analg 2011;113:449-72.  Back to cited text no. 11
    
12.
Denault AY, Couture P, Buithieu J, Haddad F, Carrier M, Babin D, et al. Left and right ventricular diastolic dysfunction as predictors of difficult separation from cardiopulmonary bypass. Can J Anaesth 2006;53:1020-9.  Back to cited text no. 12
    
13.
Kapoor PM, Chowdhury U, Mandal B, Kiran U, Karnatak R. Trans-esophageal echocardiography in off-pump coronary artery bypass grafting. Ann Card Anaesth 2009;12:167.  Back to cited text no. 13
[PUBMED]  Medknow Journal  
14.
Dobbs HA, Bennett-Guerrero E, White W, Shernan SK, Nicoara A, Mauricio Del Rio J, et al. Multinational institutional survey on patterns of intraoperative transesophageal echocardiography use in adult cardiac surgery. J Cardiothorac Vasc Anesth 2014;28:54-63.  Back to cited text no. 14
    
15.
Shim JK, Choi YS, Chun DH, Hong SW, Kim DH, Kwak YL. Relationship between echocardiographic index of ventricular filling pressure and intraoperative haemodynamic changes during off-pump coronary bypass surgery. Br J Anaesth 2009;102:316-21.  Back to cited text no. 15
    
16.
McIlroy DR, Lin E, Durkin C. Intraoperative transesophageal echocardiography: A critical appraisal of its current role in the assessment of diastolic dysfunction. J Cardiothorac Vasc Anesth 2015;29:1033-43.  Back to cited text no. 16
    
17.
Nicoara A, Whitener G, Swaminathan M. Perioperative diastolic dysfunction: A comprehensive approach to assessment by transesophageal echocardiography. Semin Cardiothorac Vasc Anesth 2013;18:218-236.  Back to cited text no. 17
    
18.
Morganstern J, Kanchuger M. Pro: All off-pump coronary artery bypass graft surgeries should include intraoperative transesophageal echocardiography assessment. J Cardiothorac Vasc Anesth 2008;22:625-8.  Back to cited text no. 18
    
19.
Gurbuz AT, Hecht ML, Arslan AH. Intraoperative transesophageal echocardiography modifies strategy in off-pump coronary artery bypass grafting. Ann Thorac Surg 2007;83:1035-40.  Back to cited text no. 19
    
20.
Mishra M, Malhotra R, Mishra A, Meharwal ZS, Trehan N. Hemodynamic changes during displacement of the beating heart using epicardial stabilization for off-pump coronary artery bypass graft surgery. J Cardiothorac Vasc Anesth 2002;16:685-90.  Back to cited text no. 20
    
21.
Couture P, Denault A, Limoges P, Sheridan P, Babin D, Cartier R. Mechanisms of hemodynamic changes during off-pump coronary artery bypass surgery. Can J Anaesth 2002;49:835-49.  Back to cited text no. 21
    

Top
Correspondence Address:
Deepak Prakash Borde
Ozone Anesthesia Group, 1st Floor, United CIIGMA Hospital, Shahnoorwadi, Aurangabad - 431 001, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-9784.179591

Rights and Permissions


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6], [Figure 7], [Figure 8], [Figure 9], [Figure 10], [Figure 11], [Figure 12], [Figure 13], [Figure 14], [Figure 15]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4]



 

Top