CASE REPORT  
Year : 2015  |  Volume : 18  |  Issue : 2  |  Page : 257-260
Anticoagulation dilemma in a high-risk patient with On-X valves


Department of Anesthesiology and Perioperative Medicine, Medical College of Georgia, Georgia Regents University, Augusta, GA, USA

Click here for correspondence address and email

Date of Submission14-Aug-2014
Date of Acceptance06-Feb-2015
Date of Web Publication2-Apr-2015
 

   Abstract 

Thromboembolism continues to be a major concern in patients with mechanical heart valves, especially in those with unsatisfactory anticoagulation levels. The new On-X valve (On-X Life Technologies, Austin, TX, USA) has been reported as having unique structural characteristics that offer lower thrombogenicity to the valve. We report a case where the patient received no or minimal systemic anticoagulation after placement of On-X mitral and aortic valves due to development of severe mucosal arterio-venous malformations yet did not show any evidence of thromboembolism. This case report reinforces the findings of recent studies that lower anticoagulation levels may be acceptable in patients with On-X valves and suggests this valve may be particularly useful in those in whom therapeutic levels of anticoagulation cannot be achieved due to increased risk of bleeding.

Keywords: Anticoagulation; On-X valve; Thromboembolism

How to cite this article:
Karkar AM, Castresana MR, Odo N, Agarwal S. Anticoagulation dilemma in a high-risk patient with On-X valves. Ann Card Anaesth 2015;18:257-60

How to cite this URL:
Karkar AM, Castresana MR, Odo N, Agarwal S. Anticoagulation dilemma in a high-risk patient with On-X valves. Ann Card Anaesth [serial online] 2015 [cited 2019 Nov 14];18:257-60. Available from: http://www.annals.in/text.asp?2015/18/2/257/154496



   Introduction Top


Currently available mechanical heart valves (MHVs) have acceptable durability and hemodynamics, however, thromboembolism continues to be a concern, especially in patients with unsatisfactory anticoagulation levels. [1] A relatively new MHV, the bileaflet On-X valve (On-X Life Technologies, Austin, TX, USA) is believed to have greater thromboresistance because of its all-carbon manufacturing and improved flow dynamics. Preliminary short- and intermediate-term studies have shown that this valve could possibly reduce anticoagulation requirements. [2],[3],[4],[5],[6],[7] In this case report, we discuss the critical need to balance anticoagulation therapy with the potential for life-threatening protracted bleeding in a patient with two freshly implanted On-X valves.


   Case Report Top


A 57-year-old woman with severe rheumatic mitral stenosis, severe aortic stenosis, and severe tricuspid regurgitation underwent implantation of a 25 mm mitral and a 19 mm aortic On-X valve, a de Vega tricuspid annuloplasty, and Maze procedure. The cardiopulmonary bypass and aortic cross-clamp times were 174 and 134 min, respectively. She had chronic atrial fibrillation, hypertension, and pacemaker placement for sick sinus syndrome, and was on warfarin, but denied any history of bleeding in the past. Her preoperative echocardiogram and right heart catheterization revealed severe pulmonary hypertension with pulmonary arterial systolic pressures of 75 mmHg and severe right ventricular dilatation.

She came to the intensive care unit (ICU) intubated and on high infusion rates of inotropic and vasopressor agents including epinephrine, norepinephrine, vasopressin, and milrinone. Despite multiple blood component therapy intraoperatively, she continued to be severely hypocoagulable, with thrombocytopenia, hypofibrinogenemia, and elevated international normalized ratio (INR) levels [Figure 1] and [Figure 2]. As her coagulation parameters began to normalize, she was started on subcutaneous heparin 5000 IU every 12 h for prophylaxis against deep vein thrombosis on postoperative day (POD) 8. However, neither antiplatelet therapy nor therapeutic heparinization was initiated due to the patient's precarious medical condition. Despite this, immediately after removal of the epicardial pacing wires on POD 9, she developed pericardial tamponade requiring emergent opening of the sternum. This led to progressive worsening of pulmonary hypertension, causing severe right heart failure and eventually biventricular failure, necessitating placement of an intra-aortic balloon pump and inhalational epoprostenol therapy. The patient developed renal failure which required continuous renal replacement therapy and compounded coagulopathy by causing consumptive thrombocytopenia and thrombocytopathia.
Figure 1: Wild fluctuations in platelet count from preoperative visit until discharge on postoperative day 166. Intervals between time points on the x-axis are variable

Click here to view
Figure 2: Patient's international normalized ratio (INR) from preoperative visit until discharge on postoperative day 166, showing subtherapeutic INR at multiple time points throughout the Intensive care unit stay

Click here to view


Three weeks after surgery, she progressed to disseminated intravascular coagulopathy (DIC) and was given multiple blood component transfusions including desmopressin, cryoprecipitate, and factor VII. After the DIC was resolved, she exhibited waxing and waning coagulopathy and thrombocytopenia [Figure 1] and [Figure 2]. Interestingly, around 6 weeks into her ICU stay, she developed profuse, life-threatening bleeding from the respiratory and upper gastrointestinal tracts and natural orifices in response to any attempts to initiate anticoagulation, even with prophylactic doses of heparin. Diagnostic bronchoscopy and upper and lower gastrointestinal endoscopies revealed extensive arteriovenous malformations (AVMs) throughout her respiratory and gastrointestinal tracts. Due to the lack of preoperative endoscopy and the fact that AVMs were not restricted to the colon, making a definitive diagnosis of Heyde's syndrome with acquired von Willebrand factor deficiency was difficult. However, there is also a possibility that some degree of aortic valve patient-prosthetic mismatch could have caused a variant of Heyde's syndrome. The patient therefore received little or no anticoagulation for almost her entire hospital stay. During her 5 months in the ICU, frequent transthoracic and transesophageal echocardiographic examinations revealed no valve thrombi. She was discharged to a long-term acute care facility on aspirin and warfarin with a subtherapeutic INR of 1.6, in view of her higher risk for bleeding. There was no history of thromboembolism and no further bleeding episodes. She died about 3 months later at an outside hospital due to pulmonary aspiration and sepsis.


   Discussion Top


In the USA, there is a growing number of valve replacements in patients of all age groups. [1] While MHVs are more durable than tissue valves, they are also thrombogenic and, therefore, require life-long anticoagulation based on American Heart Association (AHA) guidelines to prevent valve thrombosis. These guidelines may not be achievable in those at high-risk of bleeding, creating a therapeutic dilemma as thromboembolism due to inadequate anticoagulation can have dire consequences at any age. The new On-X valve is said to have several structural characteristics that may confer a certain degree of thromboresistance as compared to the other MHVs and may prove to be especially beneficial in such circumstances.

The On-X valve - Structural and hemodynamic characteristics

The US Food and Drug Administration approved the On-X aortic valve in 2001 and the On-X mitral valve in 2002. The pure pyrolytic carbon used in the construction of these valves makes them more wear-resistant without the need for silicon carbide. [8],[9] The absence of silicone alloy allows for a smoother finish and greater biocompatibility, which may decrease thrombogenicity. According to the manufacturer, several properties of the valve including flared inlet design, elongated orifice, smooth contours of the pivots, and opening of the valve leaflets to a full 90 degrees, may improve flow dynamics across the valve and provide more thromboresistance than other MHVs (On-X Life Technology information. Available at: http://www.onxlti.com/. Accessed April 01, 2015) [Figure 3].
Figure 3: On-X prosthetic heart valve design and features. (1) Pure carbon, (2) Optimal longer length (3) Inlet flared orifice, (4) Full 90° leaflet opening, (5) Stasis-free pivots, (6) Two-point leaflet closure (with permission from On-X Life Technologies, Inc., Austin, Texas, USA

Click here to view


Intraoperative and early postoperative echocardiographic data have shown increased effective orifice area and reduced transvalvular gradients as compared to St. Jude MHVs (St. Jude Medical Inc., St. Paul, MN, USA). [10],[11] In a randomized comparison with the Carbomedics Top Hat valve (Carbomedics Inc., Austin, TX, USA), the On-X valve had a significantly better hemodynamic profile, including effective orifice area, peak velocity, and peak and mean pressure drop across the valve in the immediate postoperative period. [12] MHVs in general cause significant hemolysis with reports of lactate dehydrogenase (LDH) levels increasing up to 200% of upper normal. However, both aortic and mitral On-X valves have shown much lower LDH levels at up to 1 year after implantation. [13]

The On-X valve - Anticoagulation profile

Coagulation-related complications of MHVs range from a fatal thromboembolism due to inadequate anticoagulation at one end of the spectrum to equally devastating anticoagulation-induced bleeding at the other end. In several short- and intermediate-term multi-center American and European studies, On-X valves have performed favorably compared to other MHVs. [2],[3],[4],[5],[6]

Most recently, in a 5-year prospective observational study, 737 patients who underwent On-X valve replacement in aortic and/or mitral positions were maintained at an INR of 2.0-2.5 for aortic valve replacements (AVR) and 2.0-3.0 for mitral valve replacements (MVR). The results showed a 5-year freedom from major thromboembolism of 96.5% for AVR and 97.7% for MVR and from hemorrhage of 93.6% for AVR and 95.7% for MVR. Thromboembolism and hemorrhage were seen only when there was a deviation in the desired INR ranges. [7]

In another study, clinical performance of the On-X valves was compared with the Carbomedics and Medtronic Hall valves (Medtronic, Inc., Minneapolis, MN, USA) in the challenging setting of a Third World population. Target INR was 1.5-2.5 to minimize bleeding, with several patients receiving either no or incomplete anticoagulation coverage. This study showed that in the aortic position, there were no significant differences in thromboembolic complications among the three valves; however in the mitral position, both Medtronic Hall and On-X valves performed favorably as compared to the Carbomedics valve (Carbomedics Inc., Austin, TX, USA). [14]

Anticoagulation for mechanical and tissue valves versus On-X valves

According to current AHA guidelines, patients with mechanical and tissue valves should be anticoagulated for 3 months postoperatively for an INR between 2.5 and 3.5. While biological valve patients may be switched over to aspirin after that, those with MHVs should be continued on warfarin to maintain INR levels of 2.0-3.0 for low-risk AVR patients without risk of thromboembolism and 2.5-3.5 for all MVR patients and high-risk AVR patients. [15]

At this time, no standard INR ranges to prevent thromboembolism are recommended for On-X valves. The Prospective Randomized On-X Valve Reduced Anticoagulation Clinical Trial is presently underway to examine whether a lower level of anticoagulation may be acceptable. [16] In the protocol, all patients will receive standard anticoagulation therapy for the first 3 months followed by aspirin 325 mg/day and clopidogrel 75 mg/day for low-risk AVR; warfarin to maintain INR of 1.5-2.0 paired with aspirin 81 mg/day for high-risk AVR; and warfarin to maintain INR of 2.0-2.5 along with aspirin 81 mg/day for all MVRs. Results of the phase I study involving high-risk AVRs showed reduced frequency of minor and major bleeding events without increased risk of thromboembolism in the test group receiving warfarin to maintain INR of 1.5-2.0 and low-dose aspirin therapy. [16]

Retrospective studies have shown that anticoagulation has been safely held for 1-2 weeks in MHV patients with intracranial hemorrhages or ischemic strokes who are at a very high-risk for worsening of hemorrhage or conversion to a hemorrhagic stroke. [17],[18] However, our patient remained off any type of anticoagulation for several months without any clinical evidence of valve thrombosis or embolism. While we do not endorse defying those recommendations, based on recent data that have suggested lower thrombogenicity of On-X valves and the absence of thromboembolism in our patient, it may be possible to accept lower anticogulation levels in those at a very high-risk of bleeding. In the future, the On-X valve could well become the valve of choice for such patients; however, further randomized trials are needed to determine the safety and efficacy of maintaining lower anticoagulation levels.

 
   References Top

1.
Butany J, Ahluwalia MS, Munroe C, Fayet C, Ahn C, Blit P, et al. Mechanical heart valve prostheses: Identification and evaluation (erratum). Cardiovasc Pathol 2003;12:322-44.  Back to cited text no. 1
    
2.
Moidl R, Simon P, Wolner E, On-X Prosthesis Heart Valve Trial. The On-X prosthetic heart valve at five years. Ann Thorac Surg 2002;74:S1312-7.  Back to cited text no. 2
    
3.
Ozyurda U, Akar AR, Uymaz O, Oguz M, Ozkan M, Yildirim C, et al. Early clinical experience with the On-X prosthetic heart valve. Interact Cardiovasc Thorac Surg 2005;4:588-94.  Back to cited text no. 3
    
4.
Palatianos GM, Laczkovics AM, Simon P, Pomar JL, Birnbaum DE, Greve HH, et al. Multicentered European study on safety and effectiveness of the On-X prosthetic heart valve: Intermediate follow-up. Ann Thorac Surg 2007;83:40-6.  Back to cited text no. 4
    
5.
Laczkovics A, Heidt M, Oelert H, Laufer G, Greve H, Pomar JL, et al. Early clinical experience with the On-X prosthetic heart valve. J Heart Valve Dis 2001;10:94-9.  Back to cited text no. 5
    
6.
McNicholas KW, Ivey TD, Metras J, Szentpetery S, Marra SW, Masters RG, et al. North American multicenter experience with the On-X prosthetic heart valve. J Heart Valve Dis 2006;15:73-8.  Back to cited text no. 6
    
7.
Chan V, Jamieson WR, Lam BK, Ruel M, Ling H, Fradet G, et al. Influence of the On-X mechanical prosthesis on intermediate-term major thromboembolism and hemorrhage: A prospective multicenter study. J Thorac Cardiovasc Surg 2010;140:1053-8.e2.  Back to cited text no. 7
    
8.
Ma L, Sines GH. Unalloyed pyrolytic carbon for implanted mechanical heart valves. J Heart Valve Dis 1999;8:578-85.  Back to cited text no. 8
    
9.
Ely JL, Emken MR, Accuntius JA, Wilde DS, Haubold AD, More RB, et al. Pure pyrolytic carbon: Preparation and properties of a new material, On-X carbon for mechanical heart valve prostheses. J Heart Valve Dis 1998;7:626-32.  Back to cited text no. 9
    
10.
Fraund S, Pethig K, Wahlers T, Harringer W, Wiebe K, Strüber M, et al. ON-X bileaflet valve in aortic position - Early experience shows an improved hemodynamic profile. Thorac Cardiovasc Surg 1998;46:293-7.  Back to cited text no. 10
    
11.
Walther T, Falk V, Tigges R, Krüger M, Langebartels G, Diegeler A, et al. Comparison of On-X and SJM HP bileaflet aortic valves. J Heart Valve Dis 2000;9:403-7.  Back to cited text no. 11
    
12.
Chambers J, Roxburgh J, Blauth C, O'Riordan J, Hodson F, Rimington H. A randomized comparison of the MCRI On-X and CarboMedics Top Hat bileaflet mechanical replacement aortic valves: Early postoperative hemodynamic function and clinical events. J Thorac Cardiovasc Surg 2005;130:759-64.  Back to cited text no. 12
    
13.
Birnbaum D, Laczkovics A, Heidt M, Oelert H, Laufer G, Greve H, et al. Examination of hemolytic potential with the On-X (R) prosthetic heart valve. J Heart Valve Dis 2000;9:142-5.  Back to cited text no. 13
    
14.
Williams MA, Crause L, Van Riet S. A comparison of mechanical valve performance in a poorly anticoagulated community. J Card Surg 2004;19:410-4.  Back to cited text no. 14
    
15.
Bonow RO, Carabello B, de Leon AC Jr, Edmunds LH Jr, Fedderly BJ, Freed MD, et al. Guidelines for the management of patients with valvular heart disease: Executive summary. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Management of Patients with Valvular Heart Disease). Circulation 1998;98:1949-84.  Back to cited text no. 15
    
16.
Puskas J, Gerdisch M, Nichols D, Quinn R, Anderson C, Rhenman B, et al. Reduced anticoagulation after mechanical aortic valve replacement: Interim results from the prospective randomized on-X valve anticoagulation clinical trial randomized Food and Drug Administration investigational device exemption trial. J Thorac Cardiovasc Surg 2014;147:1202-10.  Back to cited text no. 16
    
17.
Phan TG, Koh M, Wijdicks EF. Safety of discontinuation of anticoagulation in patients with intracranial hemorrhage at high thromboembolic risk. Arch Neurol 2000;57:1710-3.  Back to cited text no. 17
    
18.
Wijdicks EF, Schievink WI, Brown RD, Mullany CJ. The dilemma of discontinuation of anticoagulation therapy for patients with intracranial hemorrhage and mechanical heart valves. Neurosurgery 1998;42:769-73.  Back to cited text no. 18
    

Top
Correspondence Address:
Dr. Shvetank Agarwal
Department of Anesthesiology and Perioperative Medicine, Medical College of Georgia, Georgia Regents University, 1120, 15th Street, BI-2144, Augusta, GA 30912
USA
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-9784.154496

Rights and Permissions


    Figures

  [Figure 1], [Figure 2], [Figure 3]



 

Top