ACA App
Annals of Cardiac Anaesthesia Annals of Cardiac Anaesthesia Annals of Cardiac Anaesthesia
Home | About us | Editorial Board | Search | Ahead of print | Current Issue | Archives | Submission | Subscribe | Advertise | Contact | Login 
Users online: 2196 Small font size Default font size Increase font size Print this article Email this article Bookmark this page
 


 

 
     
    Advanced search
 

 
 
     
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Email Alert *
    Add to My List *
* Registration required (free)  


    References
    Article Figures

 Article Access Statistics
    Viewed2092    
    Printed66    
    Emailed0    
    PDF Downloaded141    
    Comments [Add]    
    Cited by others 2    

Recommend this journal

 


 
Table of Contents
LETTER TO EDITOR  
Year : 2012  |  Volume : 15  |  Issue : 2  |  Page : 165-166
Inadvertent placement of left central venous catheter into left internal thoracic vein: A case report


Department of Cardiac Anesthesiology, Madras Medical Mission Hospital, Chennai, India

Click here for correspondence address and email

Date of Web Publication16-Apr-2012
 

How to cite this article:
Angral R, Sabesan P, Natarajan K, Ninan B. Inadvertent placement of left central venous catheter into left internal thoracic vein: A case report. Ann Card Anaesth 2012;15:165-6

How to cite this URL:
Angral R, Sabesan P, Natarajan K, Ninan B. Inadvertent placement of left central venous catheter into left internal thoracic vein: A case report. Ann Card Anaesth [serial online] 2012 [cited 2019 Dec 10];15:165-6. Available from: http://www.annals.in/text.asp?2012/15/2/165/95086


The Editor,

Central venous catheter (CVC) placement is a routine procedure in the management of patients undergoing coronary artery bypass graft (CABG). Correct placement of the CVC is an essential prerequisite for accurate monitoring of central venous pressure (CVP) and long-term use of the catheter. Malpositioning of CVC is a known complication, with the reported incidence ranging widely from less than 1% to more than 60%. [1] Malpositioning of the catheter occurs approximately 2% of the time when the subclavian or internal jugular vein (IJV) approaches are used. [2] It has been reported that the incidence of catheter malposition is 4.12% and 1.1% when the left and right IJVs are used, and it also depends on the type of material used but not on the experience of the physician who inserted the catheter. [3] We report a case of misplacement of an internal jugular catheter into the internal mammary vein before CABG. A 59-year-old obese female was scheduled for CABG. Anesthesia was induced with midazolam and fentanyl and endotracheal intubation was facilitated with vecuronium bromide and pancuronium bromide. [4] The left IJV was cannulated with a 16 cm catheter and threading of the catheter was smooth and uneventful. Return of venous blood was observed and intravenous (i.v.) fluid flowed easily into the catheter. CVP trace was normal and was measured as 13 mmHg. We connected inotropes and nitroglycerine to the other ports and started the infusion. Following median sternotomy and spreading of the sternum apart using a chest spreader, the CVP increased to 25 mmHg from 13 mmHg. When the CVC was flushed, the surgeon noticed a spurt of fluid around the internal mammary area. The surgeon observed that the catheter had entered the left internal mammary vein [Figure 1] and there was a small hematoma in the vicinity of the internal mammary artery [5],[6] [Figure 1] and [Figure 2]. The catheter was withdrawn to a length of 10 cm. Adequate backflow was present and fluids were flowing well. After the dissection, the surgeon checked the patency of the vein, and it was found to be damaged. Proper positioning of the CVC is important to ensure optimal catheter function and to decrease complications. Many of the cases of left superior intercostal vein cannulation in the literature document the findings, with no report of patient symptoms, catheter function or management. Sekerci and colleagues [7] reported inadvertent malpositioning of a drum catheter in the left internal mammary vein following an attempt at central venous cannulation via the right antecubital fossa.
Figure 1: Showing CVC in left internal thoracic vein

Click here to view
Figure 2: Showing small tear in internal thoracic vein

Click here to view


 
   References Top

1.Malatinský J, Kadlic T, Májek M, Sámel M. Misplacement and loop formation of central venous catheters. Acta Anaesthesiol Scand 1976;20:237-47.  Back to cited text no. 1
    
2.Kaufman JL, Rodriquez JL, McFadden JA, Brolin RE. Clinical experience with the multiple lumen central venous catheter. JPEN J Parenteral Enteral Nutr 1986;10:487-9.  Back to cited text no. 2
    
3.Muhm M, Sunder-Plassmann G, Apsner R, Pernerstorfer T, Rajek A, Lassnigg A, et al. Malposition of central venous catheters. Incidence, management and preventive practices. Wien Klin Wochenschr 1997;109:400-5.  Back to cited text no. 3
    
4.Salmenperä M, Peltola K, Takkunen O, Heinonen J. Cardiovascular effects of pancuronium and Vecuronium during high dose fentanyl anesthesia. Anesth Analg 1983;62:1059-64.  Back to cited text no. 4
    
5.Eulmesekian PG, Perez A, Minces PG, Lobos P, Moldes J, Garcia Monaco R. Internal mammary artery injury after central venous catheterization. Pediatr Crit Care Med 2007;8:489-91.  Back to cited text no. 5
    
6.Mazeh H, Alaiyan B, Vald O, Mizrahi I, Eid A, Freund HR. Internal mammary artery injury during central venous catheter insertion for TPN; Rare but Fatal. Nutrition 2010;26:849-51.  Back to cited text no. 6
    
7.Sekerci S, Mercan S, Dönmez A, Torgay A, Arslan G. Malpositioning of the central venous catheter necessitating sternotomy. Eur J Anaesthesiol 1999;16:69-70.  Back to cited text no. 7
    

Top
Correspondence Address:
Rajesh Angral
Plot Number 176, Housing Colony, Janipur, Jammu (J&K)-180 007
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-9784.95086

Rights and Permissions


    Figures

  [Figure 1], [Figure 2]

This article has been cited by
1 Cannulation of the Internal Thoracic Artery with a Central Venous Catheter
Robert J. Lentz,Kim L. Sandler,Alison N. Miller
American Journal of Respiratory and Critical Care Medicine. 2016; 193(5): e9
[Pubmed] | [DOI]
2 Accidental placement of central venous catheter tip into internal mammary vein
SManimala Rao,Rahul Amte,Kartik Munta,PradeepM Venkategowda,JaydeepRay Chaudhary
Indian Journal of Critical Care Medicine. 2015; 19(6): 365
[Pubmed] | [DOI]



 

Top