Next article Search Articles Instructions for authors  Access Statistics | Citation Manager  
ORIGINAL ARTICLE  

 Article Access Statistics
    Viewed3733    
    Printed155    
    Emailed3    
    PDF Downloaded254    
    Comments [Add]    
    Cited by others 4    

Recommend this journal

Utility of Sonoclot analysis and tranexamic acid in tetralogy of Fallot patients undergoing intracardiac repair


1 Department of Cardiac Anaesthesia, All India Institute of Medical Sciences, New Delhi, India
2 Department of Cardiac Surgery, All India Institute of Medical Sciences, New Delhi, India

Correspondence Address:
Poonam Malhotra Kapoor
Department of Cardiac Anaesthesia, C.N. Centre, A.I.I.M.S., New Delhi - 110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-9784.91477

Rights and Permissions

Year : 2012  |  Volume : 15  |  Issue : 1  |  Page : 26-31

 

SEARCH
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles

  Article in PDF (584 KB)
Email article
Print Article
Add to My List
Sonoclot analysis is a point of care test to monitor the coagulation process, presenting a comprehensive evaluation of the clot formation and retraction as well as platelet function. This randomized double-blinded study was designed to investigate the utility of Sonoclot analysis in monitoring the coagulation profile as also the antifibrinolytic effects of tranexamic acid administered in patients with tetralogy of Fallot undergoing intracardiac repair. Eighty of a total 94 patients were randomly divided into two groups of 40 each. In the study group, TA was administered thrice at a dosage of 10 mg/kg, i.e. before CPB, on CPB and after CPB, whereas in the control group, placebo was administered at the same time intervals. Sonoclot analysis and D-dimer measurement were performed at baseline and following heparin neutralisation. An additional variable, DR 15 (diminishing rate of clot strength at 15 min postmaximal clot strength), was calculated from the Sonoclot graph and was compared with d-dimer levels as a measure of fibrinolysis. The three Sonoclot variables, i.e. activated clotting time, clot rate and platelet function, were deranged at baseline in all the patients. Post-CPB, the change in these variables was not significant. ACT, clot rate and platelet function showed no significant (P > 0.05) difference in both the groups at both the time intervals. DR 15 and d-dimer values were comparable at baseline in both the groups. However, a significant (P < 0.05) difference was seen in these variables in the control group as compared with the TA group following heparin neutralisation. To conclude, Sonoclot analysis is a useful, point of care method for the monitoring of coagulation and fibrinolysis in patients with tetralogy of Fallot undergoing intracardiac repair.






[FULL TEXT] [PDF]*
 

 

 

 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 
 
 Reader Comments
 Email Alert *
  *
 * Requires registration (Free)
 
 ORIGINAL ARTICLE
 




1 Department of Cardiac Anaesthesia, All India Institute of Medical Sciences, New Delhi, India
2 Department of Cardiac Surgery, All India Institute of Medical Sciences, New Delhi, India

Correspondence Address:
Poonam Malhotra Kapoor
Department of Cardiac Anaesthesia, C.N. Centre, A.I.I.M.S., New Delhi - 110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-9784.91477

Rights and Permissions

Sonoclot analysis is a point of care test to monitor the coagulation process, presenting a comprehensive evaluation of the clot formation and retraction as well as platelet function. This randomized double-blinded study was designed to investigate the utility of Sonoclot analysis in monitoring the coagulation profile as also the antifibrinolytic effects of tranexamic acid administered in patients with tetralogy of Fallot undergoing intracardiac repair. Eighty of a total 94 patients were randomly divided into two groups of 40 each. In the study group, TA was administered thrice at a dosage of 10 mg/kg, i.e. before CPB, on CPB and after CPB, whereas in the control group, placebo was administered at the same time intervals. Sonoclot analysis and D-dimer measurement were performed at baseline and following heparin neutralisation. An additional variable, DR 15 (diminishing rate of clot strength at 15 min postmaximal clot strength), was calculated from the Sonoclot graph and was compared with d-dimer levels as a measure of fibrinolysis. The three Sonoclot variables, i.e. activated clotting time, clot rate and platelet function, were deranged at baseline in all the patients. Post-CPB, the change in these variables was not significant. ACT, clot rate and platelet function showed no significant (P > 0.05) difference in both the groups at both the time intervals. DR 15 and d-dimer values were comparable at baseline in both the groups. However, a significant (P < 0.05) difference was seen in these variables in the control group as compared with the TA group following heparin neutralisation. To conclude, Sonoclot analysis is a useful, point of care method for the monitoring of coagulation and fibrinolysis in patients with tetralogy of Fallot undergoing intracardiac repair.